Marketplace

CHEN ZHU's Store

Owned by CHEN ZHU Joined Apr 2024 14 Listings

chat Contact Seller
store Save Business Card
storefront

CHEN ZHU's Store

easyid.me/biz/chenzhu-83a9fc • Verified Store

EasyID Store QR Code

Scan to open official EasyID digital store, view live catalog, or save business card.

verified

Verified Merchant

EasyID Certified Seller

local_shipping

Fast 24h Packing

Direct courier dispatch

lock_clock

Zero Escrow Direct

Direct merchant settlement

Store Listings (2)

search

CZ3000 Pulse Input Signal Conditioner

$200.00

Pulse voltage input signal conditioners transfer the pulse voltage signal and provide isolated power supply for field instruments. The input adopts hysteresis comparison circuit and has high anti-interference performance. It has two output way: pulse voltage output and transistor output.  <br>This 5v to 24v plc signal converter needs an independent power supply and galvanic isolation among power supply, input and output. <br> <br>Advantages of CZ3000 Pulse Input Signal Conditioner <br>24V DC independent power supply <br>PNP/NPN transistor output or voltage pulse output <br> <br>CHENZHU has got intergraded management service Certificates, like ISO9001, ISO14001 and ISO45001, more than 135 patents related core tech was obtained, reference OEM and ODM customers from German, Japan and direct shipments to any global destinations. <br>#voltage #pulse #output <br>[a]https%3A%2F%2Fwww.chenzhuisolator.com%2Fproducts%2Fcz3000-pulse-input-signal-conditioner.html[/a]

sell Health & Beauty
storefront CHEN ZHU's Store

Signal Conditioner

$200.00

Signal Conditioner <br>Universal signal conditioner is used in industrial process control systems. Isolated signal conditioner connects industrial field instruments and control systems to complete the function of signal matching and conversion. Through reliable isolation technology, the signal conditioning equipment resists various interference attacks and ensures the stability of the system and instruments in a complex electromagnetic environment. The isolated pt 100 signal conditioner of Chenzhu using special design achieves anti-interference among power supply, input, and output. At the same time, the signal conditioning isolation module/unit has a strong EMC performance that can work normally even under strong interference. <br> <br>So far, our signal conditioning amplifier for electronics, as a member of the whole safety automation system, has been applied to tens of thousands of industrial sites. And the stability of the control system escort, possessing the most complete models, has reached the international level. As one of the most professional signal isolator suppliers, Chenzhu promises to provide you good transducer signal conditioning and services! Different types of signal conditioning system for circuits can be offered by us, whether it&#039;s based on RTD loop powered digital isolator or DC Pt100 signal splitter with 4-20mA output current. If you want to know the price of our 5v to 24v PLC signal converter, please contact us as soon as possible. Related sensors and signal conditioning pdf files are also available for you to refer to. <br> <br>Signal Conditioner Types <br>CZ2000 Series Signal Conditioner <br>CZ2000 Analogue Signal Conditioner <br>CZ2000 Analogue Signal Conditioner Loop Power <br>CZ2000 Temperature Converter Signal Conditioner <br>CZ2000 Voltage/Current Input Signal Conditioner <br> <br>CZ3000 Series Signal Conditioner <br>CZ3000 Analogue Signal Conditioner <br>CZ3000 Analogue Signal Conditioner Loop Power <br>CZ3000 Temperature Converter Signal Conditioner <br>CZ3000 Pulse Input Signal Conditioner <br>CZ3000 Frequency Converter Signal Conditioner <br> <br>CZ3500 Series Bus powered Signal Conditioner <br> <br>What is the difference between 2-wire transmitter, 3-wire transmitter and 4-wire transmitter? <br>2-wire transmitter <br>2-wire transmitters are the simplest and most economical way to used them in the industrial field. The zero-end current is 4mA, which is sufficient to drive the transmitter&#039;s internal circuitry, while the current at 4-20mA represents the range of process transmissions measured. <br> <br>3-wire transmitter <br>Some transmitter require more power than the signal loop can supply their internal circuity. The three-wire current output can share a ground wire with the power supply, saving a wire. <br> <br>4-wire transmitter <br>Four-wire transmitters have their own internal power supply, and they do not need to be connected to a DC power supply. It has two power cords and two current output lines. The output of a 4-wire transmitter is usually a current signal. <br> <br>FAQ of Signal Isolators <br>Q <br>How to distinguish between the active and passive signals? <br>A <br>According to whether the signal acquisition loop needs an external power supply, <br> <br>Active signal:In the 4~20mA signal acquisition loop, the signal generating end has its own voltage drive and no external power supply equipment is needed. This 4~20mA is an active signal. Generally, 4-wire transmitter and 3-wire transmitter output active signals. <br> <br>Passive signal:In the 4~20mA signal acquisition loop, the signal generating end does not have its own voltage drive and external power supply equipment is needed. This 4~20mA is a passive signal. Generally, a 2 wire temperature transmitter outputs passive signals. <br> <br>Method of judging whether the external power supply is needed in the signal acquisition loop: <br> <br>Disconnect the signal acquisition loop, and connect a voltmeter to the two lines of the field device (voltage transmitter). If there is voltage, it means the field device outputs active signals. If there is no voltage, it means the field device outputs passive signals. <br> <br>Temperature Input Signal Type and Range <br> Range Min. Span Accuracy <br>Type <br>TC T -200℃~+400℃ 50℃ 0.5℃/0.1% <br> E -200℃~+900℃ 50℃ 0.5℃/0.1% <br> J -200℃~+1200℃ 50℃ 0.5℃/0.1% <br> K -200℃~+1372℃ 50℃ 0.5℃/0.1% <br> N -200℃~+1300℃ 50℃ 0.5℃/0.1% <br> R -40℃~+1768℃ 500℃ 1.5℃/0.1% <br> S -40℃~+1768℃ 500℃ 1.5℃/0.1% <br> B +320℃~+1820℃ 500℃ 1.5℃/0.1% <br>RTD Pt100 -200℃~+850℃ 20℃ 0.2℃/0.1% <br> Cu50 -50℃~+150℃ 20℃ 0.2℃/0.1% <br> Cu100 -50℃~+150℃ 20℃ 0.2℃/0.1% <br>mV -100mV~+100mV 10mV 20μV/0.1% <br>Potentiometer 0~5kΩ 0.10% <br> 0~10kΩ 0.10% <br> <br>Note of the data of loop powered isolators: <br> <br>1. The“%” of conversion accuracy is relative to its range. Take the larger value between the range error and the absolute error when applying. <br> <br>2. Allow a maximum wire resistance of 50Ω/line for RTD input(3-wire). <br> <br>3. When the thermocouple is input, the conversion accuracy does not include the CJC. For every 100Ω increase in the compensation wire, the cold junction error increases by 0.2°C. <br> <br>4. When the Type B thermocouple is input, the lower limit of temperature range is required to be greater than 680 °C to ensure the accuracy index. <br> <br>5. mV signal input needs to be customized. <br> <br>CHENZHU manufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system. <br>#isolated#signal#conditioner <br> <br>[a]https%3A%2F%2Fwww.chenzhuisolator.com%2Fproducts%2Fsignal-conditioner%2F%0A%0A%0A[/a]

sell Health & Beauty
storefront CHEN ZHU's Store

About CHEN ZHU's Store

No description provided.

0.0

star star star star star
0 Reviews

Customer Reviews

See what others are saying about CHEN ZHU's Store. We verify purchases to ensure reviews are genuine.

reviews

No reviews yet for this store.